PN: ICVR400  

ICVR Low Loss Cable ICVR400  

Construction Specification   Item  Material  Diameter(mm)   1. Inner Conductor   Copper Clad Aluminum   2.74   2. Dielectric   Physical Foam Polyethylene   7.24   3. Outer Conductor

PRICE
Request a Quote
Please contact us for pricing details
Quick Actions

Construction Specification

  Item  Material  Diameter(mm)
  1. Inner Conductor   Copper Clad Aluminum   2.74
  2. Dielectric   Physical Foam Polyethylene   7.24
  3. Outer Conductor   Bonded Aluminum Foil + Tinned Copper Braid   Nom.8.1
  4. Jacket   Polyethylene   10.16

Electrical Characteristics

  Capacitance(pF/m)   78.4
  Impedance(ohm)   50
  Velocity of Propagation(%)   85
  Inner Conductor DC Resistance(ohm/m)   4.91
  Outer Conductor DC Resistance(ohm/m)   5.41
  Jacket Voltage Withstanding(Vrms)   8000
  Peak Power(KW)   16
  Shielding Effectiveness(>dB)   90

Mechanical and Environmental Characteristics

  Operating Temp(℃)   -40 to +80 
  Bending Radius(mm)   51
  ROHS   Compliant 

Attenuation and Avg. Power(20℃)

  Frequency(MHz)  Attenuation(dB/100m)  Avg. Power(KW)
  30   2.2   2.91
  50   2.9   2.21
  150   5.0   1.28
  220   6.1   1.05
  450   8.9   0.72
  900   12.8   0.50
  1500   16.8   0.38
  1800   18.6   0.34
  2000   19.6   0.33
  2500

  22.2

  0.29
  5800   35.5   0.18