PART NUMBER
RLA440001
BNC Lightning Arrester

BNC Male to BNC Female Lightning Arrester ,DC-3GHz

MECHANICAL DRAWING / DIMENSIONS (mm)

The RF coaxial surge protector, also commonly referred to as an RF lightning arrester, serves as an indispensable protective part for steady operation within contemporary communication systems.It is installed in series along the signal path between antennas and receiving devices like base stations and satellite receivers. Engineered professionally, this device is built to release transient overvoltage and surge current generated by lightning surges or grid instability on transmission lines.It rapidly conducts dangerous surge energy to the ground in nanoseconds, delivering reliable safeguarding for high-value, precision-sensitive electronic devices at the backend and preventing irreversible equipment damage.By reducing unexpected network outages and economic losses resulting from lightning impacts, this series becomes a must-have solution for constructing high-stability outdoor communication network infrastructure.

A full selection of connector styles and port combinations is available to meet diverse on-site installation demands:

Interface Specifications: N-Type, TNC, SMA, BNC, UHF, DIN 7/16.

Structural Configurations: Male to Female, Male to Male, Female to Female, along with bulkhead mounting models for stable cabinet and panel installation.

Impedance Options: 50Ω and 75Ω two mainstream specifications, fully compatible with various communication system impedance standards.

Notice: INERGEK reserves the right to make modifications deemed appropriate.
🌐 www.inergek.com    ✉ [email protected]    ☎ +86 189 7105 6957
INERGEK
INDUSTRIAL ENGINEERING & CONNECTIVITY
PART NUMBER
RLA440001
Notice: INERGEK reserves the right to make modifications deemed appropriate.
🌐 www.inergek.com    ✉ [email protected]    ☎ +86 189 7105 6957
Material and Plating
Parameter Material Plating
Body Brass Ternary Alloy Plating
Insulator PTFE N/A
Contact Pin Phosphor Bronze Gold Plating
Coupling Nut Brass Nickel Plating
Interface
Parameter Connector 1 Connector 2
Type BNC BNC
Standard IEC 61169-8 IEC 61169-8
Electrical Data
Impedance (Ohm) 50 Ohm
DWV (at sea level) 2500V
Working Voltage (at sea level) 1000V
Frequency range(GHz) DC-3GHz
VSWR <1.20
Rated DC voltage 230V
Ground wire diameter ≤8 mm2
Maximum impluse discharge current 20kA
Mechanical Data
Parameter BNC
Recommended Coupling Nut Torque Bayonet
Coupling Proof Torque N/A
Coupling Nut Retention Force ≥ 101 lbs
Contact Captivation-axial ≥ 6.0 lbs
Durability (mating) ≥ 500
Environmental Data
Temperature Range -40°C to +125°C
Thermal Shock MIL-STD-202, Method 107, Condition B
Moisture Resistance MIL-STD-202, Method 106
Corrosion MIL-STD-202, Method 101, Condition B
RoHS Compliant